RecruitingNCT04708288

To Evaluate the Safety and Clinical Performance of the ARCHIMEDES Biodegradable Biliary and Pancreatic Stent

A PROSPECTIVE, MULTI-CENTER, SINGLE-ARM, POST MARKET OBSERVATIONAL STUDY TO EVALUATE THE SAFETY AND CLINICAL PERFORMANCE OF THE ARCHIMEDES BIODEGRADABLE BILIARY AND PANCREATIC STENT


Sponsor

QualiMed Innovative Medizinprodukte GmbH

Enrollment

198 participants

Start Date

Oct 3, 2020

Study Type

OBSERVATIONAL

Conditions

Summary

Significant experience with biodegradable materials has been reported in the orthopedic literature; in particular; biodegradable stents have been used in the endovascular and urologic epithelium. Stents are typically made from polymeric materials including Polylactic Acid (PLA), Polyglycolide (PGA), Polydioxanone (PDO), Polyethyleneglycol (PEG), Polycaprolactone (PCL), etc., which have been cleared or approved by the FDA and CE-marked as drug carriers, sutures, and bone fixatives. The material is degraded by hydrolysis in, e.g., lactic acid, which is removed from the body by normal metabolic pathways. In the field of gastroenterology, these stents were first introduced in patients with an esophageal stenosis with encouraging results, although esophageal hyperplasia was a frequently encountered complication. For biliary applications, biodegradable stents have been evaluated in several in-vitro and animal studies that demonstrated that the stents were safe and well tolerated. These stents provided an adequate radial force and resulted in complete stricture resolution within several months. The stents did not show any signs of biliary hyperplasia or integration in the epithelium. Moreover, they seem to have a self-clearing effect on attached biofilm as the outer layer sloughs during the degradation process similarly to the exfoliation of human skin. Also, the stent could be removed from the bile duct, thus offering the possibility of extraction if necessary at various times after implantation. In 2010, Petryl was the first to use a biodegradable stent in the human bile duct. A stent was successfully placed using percutaneous transhepatic cholangiograpy in two patients with a postsurgical intrahepatic biliary stricture. Transient cholangitis was the only complication encountered and during the two years of follow-up, the bile duct remained patent. Later, Mauri et al. presented in 2013 and 2016 results of a 107 patient study on a polydioxanone biodegradable biliary stent. The results have been published in the Journal of the European Society of Radiology. The authors concluded that percutaneous placement of a biodegradable biliary stent is a feasible and safe strategy to treat benign biliary strictures refractory to standard bilioplasty, with promising results in the mid-term period. Prior to this study, the ARCHIMEDES device was assessed in the ARCHIMEDES Investigational study which has completed enrolment with 53 patients included, and the results are not yet published. In this study approximately half the stents were deployed in the bile duct (53%) and half in the pancreatic duct. All 53 patients have either completed, exited, or no longer have the study device. No patient remains in the study with a stent in place during the time of the last patient follow-ups. The study concluded without any device-related SAE. Bilirubin was reduced by 25.6%, which exceeded the \>20% clinical success criterion, quality of life score improved from 3.7 to 7.9, procedural success was rated 1.4 (good to excellent), and technical success was achieved in all 53 patients. Data from the ARCHIMEDES Investigational study was used for CE Mark approval, which was obtained in June 2018.


Eligibility

Min Age: 18 Years

Plain Language Summary

Simplified for easier understanding

This clinical trial is studying a medical device called ARCHIMEDES Biodegradable Biliary and Pancreatic Stent for people with obstructed biliary and pancreatic duct. The study is currently recruiting participants at 11 locations.

This summary was AI-generated to explain the trial in plain language. It is not medical advice. Always discuss eligibility with your doctor before enrolling in a clinical trial.

Interested in this trial?

Get notified about updates and connect with the research team.

Interventions

DEVICEARCHIMEDES Biodegradable Biliary and Pancreatic Stent

Patients will treated with ARCHIMEDES Biodegradable Biliary and Pancreatic Stent in routine clinical practice


Locations(11)

HUS Helsinki University Hospital

Helsinki, Finland

Hôpital Européen Georges-Pompidou HEGP Service d'Hépato-gastro-entérologie et endoscopies digestives

Paris, France

Evangelisches Krankenhaus Düsseldorf

Düsseldorf, Germany

Emek Medical Center

Afula, Israel

Endoscopy Unit, Humanitas Research Hospital

Rozzano, Milano, Italy

AUSL Romagna Ospedale Morgagni - Pierantoni

Forlì, Italy

Gastroenterology and Digestive Endoscopy Unit Fondazione I.R.C.C.S. Policlinico San Matteo

Pavia, Italy

UCBM - Campus Bio-Medico University

Roma, Italy

Tan Tock Seng Hospital Pte Ltd,

Singapore, Singapore

University Medical Center Ljubljana

Ljubljana, Slovenia

Hospital Universitario de Salamanca

Salamanca, Spain

View Full Details on ClinicalTrials.gov

For the most up-to-date information, visit the official listing.

Visit

NCT04708288