RecruitingNot ApplicableNCT05790603

Effect of Patent Hemostatic Device (PHD) With Quantitative Pressure on Radial Artery Hemostasis After CAG/PCI

Effect of Patent Hemostatic Device (PHD) With Quantitative Pressure on Radial Artery Hemostasis After CAG/PCI:a Randomized Controlled Trial


Sponsor

Peking University First Hospital

Enrollment

200 participants

Start Date

May 21, 2024

Study Type

INTERVENTIONAL

Conditions

Summary

The objective of this clinical trial is to compare the hemostatic effect of 2 hemostatic devices with or without quantitative pressure on radial arteries after coronary angiography (CAG) or percutaneous coronary intervention (PCI). The main questions aims to answer: * What is the hemostatic effect of the patent hemostatic device with quantitative pressure after percutaneous coronary intervention? * What are the precise hemostatic pressure and hemostatic time of the radial artery after CAG/PCI? Participants will be randomly assigned to the intervention group (IG) and control group (CG). The IG will use patent hemostatic device with quantitative pressure (PHDQP-Band, China) while the CG will use the conventional radial artery hemostatic device (TR-Band, Japan) without pressure monitoring. The primary outcomes is incidence of 24h radial artery occlusion (24h RAO). Secondary outcomes include time to hemostasis, bleeding, hematoma, 30d radial artery occlusion (30d RAO), pain, hand swelling, numberness, pseudoaneurysm, and radial artery stenosis.


Eligibility

Min Age: 18 YearsMax Age: 80 Years

Inclusion Criteria1

  • Patients undergoing coronary angiography or percutaneous coronary intervention via the radial artery; Positive Allen's test result; Willing to sign informed consent.

Exclusion Criteria1

  • Radial artery malformation; Chronic kidney disease with eGFR<30ml/min.1.73m2; Cirrhosis of the liver; Coagulation disfunction; Patients treated with IIb / IIIa receptor antagonist.

Interested in this trial?

Get notified about updates and connect with the research team.

Interventions

DEVICEIntervention group with PHD-Band

The initial compression pressure was systolic blood pressure plus 10mmHg. Pressure will be released by 20mmHg and 40mmHg 1 hour and 2 hours respectively after the surgery and then the band will be removed after 3 hours if no bleeding occurs. The compression will continue if bleeding occurs.

DEVICEControl group with TR-Band

TR-Band will be inflated with 15 mL of air The band will be deflated with 1 mL of air hourly for the following 2 hours after the procedure. After 3 hours, the band will be removed if no bleeding occurs. If rebleeding occurs, the band will be inflated with appropriate volume of air until bleeding stops .


Locations(2)

Xuanwu Hospital

Beijing, Beijing Municipality, China

Peking University First Hospital

Beijing, China

View Full Details on ClinicalTrials.gov

For the most up-to-date information, visit the official listing.

Visit

NCT05790603


Related Trials