RecruitingNot ApplicableNCT05851326

Low-Energy Ultrasound, Electrical and Magnetic Field Stimulation in Therapy-Resistant Myofascial Pain Syndrome

A Combination of Low-Energy Ultrasound, Electrical and Magnetic Field Stimulation in Patients With Therapy-Resistant Myofascial Pain Syndrome: A Randomized, Controlled, Double-Blind Multi-Center Study


Sponsor

Sobet AG

Enrollment

126 participants

Start Date

May 25, 2023

Study Type

INTERVENTIONAL

Conditions

Summary

Sonodyn is an investigational device that within this clinical investigation is intended for use in patients suffering from low back pain, tension headache or neck pain, originating from therapy-resistant myofascial pain syndrome. Myofascial pain syndrome is a prevalent pain condition in the adult population and a common cause of pain and dysfunction in the musculoskeletal system. It is a trigger point-induced regional musculoskeletal pain disorder affecting one or more muscles or groups of muscles. Sonodyn is a handheld medical device that combines low-energy ultrasound, electrical and magnetic field stimulation for non-invasive transcutaneous treatment of chronic myofascial pain syndrome. Sonodyn is a battery-operated, rechargeable stimulation device to be placed over specific trigger points for associated pain patterns in the human body. It emits ultrasound, electrical and magnetic stimulation signals with a pre-defined set of parameters for each of the independently operated power sources. The study will follow a prospective, randomized, sham-controlled, double-blind parallel group design. It will be conducted as a multi-center investigation at 6 sites in Austria and Switzerland. Patients are randomized in a 2:1 ratio into Treatment and Control. * Active Sonodyn therapy (Treatment) * No therapy (Sham Control) Two types of Sonodyn devices will be used: a fully functional one for Therapy arm patients that can deliver stimulation, and a non-functional one for Control arm patients that cannot convey any energy signals to the device output. The devices will look fully identical. Randomization will be stratified by study site, pain diagnosis and sex of the patient. For each subject, after a screening phase of 1 week, patients will be treated for 3 weeks with a follow-up of additional 8 weeks, adding up to 12 weeks. During treatment patients will activate their device 3 times a day for 10 minutes each. During screening, treatment and follow-up period, all patients will twice per day report the average and maximum intensity of their pain Numeric Rating Scale (NRS). Patients will also enter the date, amount, and time of intake of rescue medication, if applicable. The primary objective of this study is to assess the impact on pain. Secondary objectives are to compare the performance between active therapy and sham, as well as to correlate changes in pain intensity with other pain related scales.


Eligibility

Min Age: 18 YearsMax Age: 99 Years

Inclusion Criteria10

  • Male or female aged 18 to 99 years at screening
  • Patient has an understanding of the study and its procedures, agrees to its provisions, and gives written informed consent prior to any study-related procedures
  • Patient is suffering from one of the following chronic pain conditions originating from myofascial pain:
  • low back pain
  • tension headache
  • neck pain
  • having been persisting for a minimum of 3 months and where myofascial pain syndrome is the pre-dominant cause for pain.
  • Patient is constant with respect to pain treatment for 1 week during the screening phase
  • A daily average NRS \>= 4 on 4 out of 7 days in the screening phase
  • Compliance with the daily status reporting requirements as demonstrated

Exclusion Criteria11

  • Patients with active implants
  • Allergy against rescue medication used during the study
  • Pregnancy
  • Mental or physical impairments that represent a source of risk for handling the device
  • Patients with cerebral spams (epilepsy)
  • Patients with psychiatric diseases or somatoform pain disorders
  • Patients with oral morphine equivalent of more than 120mg daily dose
  • Patients taking centrally acting muscle relaxants like Sirdalud or benzodiacepines
  • Patients with a contraindication against NSAID's
  • Presence of artificial joints made from methylmethacrylate or polyethylene at stimulation site
  • Presence of ferromagnetic metal implants at stimulation site, especially aneurysm clips, dental implants, etc.

Interested in this trial?

Get notified about updates and connect with the research team.

Interventions

DEVICEActive Sonodyn

Sonodyn emits ultrasound, electrical and magnetic stimulation signals with a pre-defined, fixed set of parameters for each of the independently operated power sources.

DEVICESham

Non-functional Sonodyn device that cannot convey any energy signals to the device output, however, looks and behaves fully identical as the active Sonodyn device.


Locations(6)

Schmerzambulanz, Krankenhaus der Elisabethinen Graz

Graz, Austria

Abteilung für Anästhesiologie und Intensivmedizin, Klinikum Klagenfurt am Wörthersee

Klagenfurt, Austria

Krankenhaus St. Vinzenz Zams

Zams, Austria

RSB Neurochirurgie AG, Salem-Spital Bern

Bern, Switzerland

Clinique de la Douleur, La Tour Hospital

Meyrin, Switzerland

Schmerzklinik Zürich AG

Zurich, Switzerland

View Full Details on ClinicalTrials.gov

For the most up-to-date information, visit the official listing.

Visit

NCT05851326