RecruitingNCT06866769

Efficacy of Biomarkers and CEUS Versus CTA in AAA Follow-up Post-EVAR

Comparación De La Eficacia Entre Biomarcadores Y Ecografía Con Contraste Frente a Angio-TC En El Seguimiento De Aneurismas De Aorta Abdominal (AAA) Tras Reparación Endovascular (EVAR)


Sponsor

Instituto de Investigacion Sanitaria La Fe

Enrollment

60 participants

Start Date

Jul 25, 2024

Study Type

OBSERVATIONAL

Conditions

Summary

This prospective observational study evaluates the efficacy of contrast-enhanced ultrasound and biomarker determination in the follow-up of patients with abdominal aortic aneurysm (AAA) treated with Endovascular Aneurysm Repair (EVAR). Currently, computed tomography angiography (CTA) is the standard for follow-up, although it has disadvantages such as radiation exposure and the use of iodinated contrasts. Contrast-enhanced ultrasound (CEUS), free of radiation and nephrotoxicity, and biomarkers could reduce the need for CTA minimizing the associated risks. Biomarkers will be measured before and after EVAR and CEUS will be performed at various time points and compared with CTA results to validate concordance and effectiveness in detecting endoleaks and aneurysm remodeling. The objectives include determining the efficacy of these combined methods and establishing a follow-up protocol that reduces exposure to radiation and iodinated contrast agents.


Eligibility

Min Age: 18 Years

Inclusion Criteria2

  • patients with AAA under follow-up who are going to be treated with EVAR.
  • signed informed consent to perform CTA, CEUS and for the determination of biomarkers.

Exclusion Criteria1

  • patients with inflammatory abdominal aortic aneurysms or ruptured aneurysm.

Interested in this trial?

Get notified about updates and connect with the research team.

Interventions

DIAGNOSTIC_TESTCTA

The levels of biomarkers are determined before (within 30 days prior to the procedure) and after the implantation of the stent (24-48 hours, 1 month, 3 months, 6 months, and at 1 year), along with the performance of a contrast-enhanced ultrasound. Additionally, a follow-up CT angiography is performed to validate the concordance, that is, to assess if there are changes in the biomarker values determined one month after the implantation of the stent compared to the baseline values that may suggest the presence of complications (endoleaks, infection, thrombosis, etc.).


Locations(1)

Hospital La Fe

Valencia, Valencia, Spain

View Full Details on ClinicalTrials.gov

For the most up-to-date information, visit the official listing.

Visit

NCT06866769


Related Trials