Hybrid Closed-Loop in Diabetes Post-Kidney Transplant: A Randomized Trial

Application of a Hybrid Closed-Loop Artificial Pancreas System in Patients With Diabetes After Kidney Transplantation: An Open-Label, Randomized Controlled Trial


Sponsor

Shanxi Bethune Hospital

Enrollment

30 participants

Start Date

Apr 1, 2025

Study Type

INTERVENTIONAL

Conditions

Summary

Objective: To evaluate the short-term blood glucose control effect of the closed-loop system combined with a regular insulin pump and continuous glucose monitoring (CGM) in hospitalized patients with diabetes after kidney transplantation, explore its clinical application value, and provide precise and personalized blood glucose management plans. Methods: A clinical comparative study will be conducted. This will be the first study focusing on hospitalized patients with diabetes after kidney transplantation. The advanced closed-loop system technology will be introduced. Expected Results: The study aims to fill the gap in this field, offer new ideas and solutions for clinical blood glucose management of these patients, and promote the development of diabetes treatment technologies by comparing the short-term blood glucose control effects of the closed-loop system and the regular insulin pump combined with CGM.


Eligibility

Min Age: 18 YearsMax Age: 70 Years

Plain Language Summary

Simplified for easier understanding

This clinical trial is studying Hybrid Closed-Loop Artificial Pancreas System for people with diabetes mellitus patients with kidney transplantation. The study is currently recruiting participants at 1 location. People eligible for this study include aged 18 Years to 70 Years.

This summary was AI-generated to explain the trial in plain language. It is not medical advice. Always discuss eligibility with your doctor before enrolling in a clinical trial.

Interested in this trial?

Get notified about updates and connect with the research team.

Interventions

OTHERHybrid Closed-Loop Artificial Pancreas System

The pump was loaded with ultra-short-acting insulin (Manufacturer: Novo Nordisk A/S, Denmark; Approval Number: National Drug Approval No. J20050097; Specification: 3 mL: 300 U). The total daily insulin requirement was calculated at 0.2-0.4 U/(kg·d) based on the patient's weight. During operation, the system automatically adjusted the basal rate according to the blood glucose level. After the physician issued a large-dose order based on previous treatment experience and blood glucose conditions, the nurse manually entered the large-dose treatment instruction in the AAPS software.


Locations(1)

Shanxi Bethune Hospital

Taiyuan, Shanxi, China

View Full Details on ClinicalTrials.gov