RecruitingPhase 2Phase 3NCT06969729
Evaluation of Clinical Efficacy and Safety of Aortal Stent-Graft Created Using 3D Printing Technology
Evaluation of Clinical Efficacy and Safety of Aortal Stent-graft Modelled Printing 3D Model Printing Technology - Multicenter, Randomized Clinical Trial
Sponsor
Samodzielny Publiczny Szpital Kliniczny nr 2 PUM
Enrollment
100 participants
Start Date
Nov 1, 2022
Study Type
INTERVENTIONAL
Conditions
Summary
the comparison of physician-modified stent-graft created in 3D models versus custom-made devices in the treatment of complex abdominal aortic aneurysm
Eligibility
Min Age: 18 Years
Inclusion Criteria7
- Female and male subjects age ≥ 18 2. Subject need to meet one of the following criteria:
- Subjects with juxtarenal or suprarenal abdominal aortic aneurysm, type IV thoracoabdominal aneurysm of diameter \>5.5cm (male) and 5.2cm (female)
- Subjects with juxtarenal or suprarenal abdominal aortic aneurysm, type IV thoraco-abdominal aneurysm with aneurysm growth rate ≥ 0.5cm during 6 months
- Type IA endoleak of post-implantation of abdominal stent- graft 3. Iliac arteries morphology with aortic stent graft implantation to be restored 4. Aortic segment which is proximal to aneurysm
- Length ≥20mm
- Diameter 20mm-36mm
- Aortic suprarenal angle ≤75 degrees 5. Survival \> 2 years
Exclusion Criteria18
- Female and male subjects age \<18
- Pregnancy and breast feeding
- Allergy and hypersensitivity to matherials of which the stent- graft is composed
- Hypersensitivity and contraindication to anti coagulation or contrast application to angio - CT which cannot be eliminated medically
- Coagulopathy which cannot medically treated
- Active infection which might cause stent - graft infection
- Creatinine level \> 3.0mg/dL
- Marphan syndrome, Ehlers - Denlos syndrome
- Unstable angina pectoris
- Raptured aortic aneurysm caused by cardiac insufficiency
- Unwillingness to comply with protocol procedures
- Iliac arteries morphology adequate for stent-graft implantation
- The diameter of the aortic flow lumen in reno-visceral aorta greater than 34mm
- Aortic section which is proximal to celiac artery with significant number of thrombi, calcification or changed by aneurysm
- Aorta with significant number of irregular thrombi which may lead to embolism ("shaggy aorta")
- Diameter of proximal kidney arteries which is exercisable to stenting \<4.5mm
- Devision of kidney artery which is exercisable to stenting in the distance of \<1cm of celiac artery, each of them is is in \<4.5mm in diameter
- Atypical anatomy of celiac artery in the form of separate exit of splenic and hepatic aortic artery
Interested in this trial?
Get notified about updates and connect with the research team.
Interventions
PROCEDUREPhysician-Modified Fenestrated Stent-Graft (3D-Printed Template-Guided)
Implantation of a physician-modified fenestrated stent-graft using a patient-specific 3D-printed aortic template, performed via an endovascular approach.
Locations(1)
View Full Details on ClinicalTrials.gov
For the most up-to-date information, visit the official listing.
NCT06969729
Related Trials
Nectero EAST System Clinical Study
NCT0600191839 locations
Cera™ Vascular Plug System Post-Market Clinical Follow-Up
NCT060990154 locations
Zenith® Fenestrated+ Clinical Study
NCT0487542933 locations
Poland-Italy Aortic Research Bridge Real World Registry
NCT0747619626 locations
PET Imaging of MMP Activation in AAA: Clinical Component
NCT074731021 location