iHub Stent-Graft for Iliac Artery Aneurysms: Safety, Performance, and Effectiveness Study
iHub no Tratamento de Aneurismas ilíacos: Avaliação da Segurança, Desempenho e Eficácia.
Archo Medical S.A
10 participants
May 26, 2026
INTERVENTIONAL
Conditions
Summary
The goal of this clinical trial is to evaluate the safety, performance, and Preliminary effectiveness of the iHub endoprosthesis system in treating iliac artery aneurysms in adult patients requiring endovascular repair. The study population includes both male and female adults over 18 years of age who meet the inclusion criteria for endovascular treatment of iliac artery aneurysms. The main questions it aims to answer are: Is the iHub stent-graft system safe for use in patients with iliac artery aneurysms? Does the iHub system demonstrate adequate technical performance and sustained patency over a 12-month follow-up period? Participants will undergo a minimally invasive endovascular procedure to implant the iHub endoprosthesis system. The device is designed to preserve internal iliac artery flow while excluding the aneurysmal segment. Participants will: Undergo pre-screening evaluations including clinical examination, laboratory tests, and imaging (CT angiography and ultrasound). Undergo endovascular implantation of the iHub device. Attend follow-up visits at 30, 90, 180, and 360 days post-implant to assess clinical outcomes and device performance.
Eligibility
Plain Language Summary
Simplified for easier understanding
This summary was AI-generated to explain the trial in plain language. It is not medical advice. Always discuss eligibility with your doctor before enrolling in a clinical trial.
Interested in this trial?
Get notified about updates and connect with the research team.
Interventions
Implantation of a self-expanding dual-lumen iliac branch stent-graft designed to treat iliac artery aneurysms while preserving perfusion to the internal iliac artery. The device enables connection to bridging stent-grafts directed to both the internal and external iliac arteries. It is compatible with previously implanted or concurrently implanted bifurcated aortic stent-grafts with branch diameters between 14 and 16 mm. The stent-graft is delivered endovascularly using a low-profile catheter-based system under fluoroscopic guidance. Once in position, the device is deployed via a controlled pull-back release mechanism. Radiopaque markers assist in precise alignment and facilitate the placement of bridging components.