RecruitingNot ApplicableNCT07125469

Comparing Measurements of the Aortic Valve Taken During Surgery With Those Obtained Before Surgery Using Computed Tomography Scans, in Patients Undergoing Surgical Aortic Valve Replacement

Intraoperative Assessment Versus Preoperative Multidetector Computed Tomography (MDCT) for Aortic Valve Annular Sizing in Surgical Aortic Valve Replacement (SAVR)"


Sponsor

Maria Cecilia Hospital

Enrollment

82 participants

Start Date

Jun 25, 2025

Study Type

INTERVENTIONAL

Conditions

Summary

This study aims to understand why there may be differences between the measurements of the aortic valve taken before and during surgery. Specifically, it will compare the valve size suggested by a CT scan (Computed Tomography) with the size measured during the operation using surgical tools. This will help determine which method is more accurate for selecting the right valve size in patients undergoing SAVR (Surgical Aortic Valve Replacement ).


Eligibility

Min Age: 18 Years

Inclusion Criteria4

  • Patient age 18 years or older
  • All patients with isolated severe Aortic Stenosis (AS) considered eligible for Surgical Aortic Valve Replacement (SAVR) according to the current 2023 European Society of Cardiology/European Association for Cardio-Thoracic Surgery (ESC/EACTS) guidelines for management of Valvular Heart Disease (reference 8) will be enrolled.
  • Patient is willing to comply with study procedures and is available to return to the center for follow-up visits.
  • Informed consent documentation signed and dated confirming that the patient has been adequately informed of all aspects related to his/her participation in the clinical study and is willing to participate.

Exclusion Criteria1

  • Bicuspid aortic valve anatomy Moderate to severe aortic valve regurgitation Multivalvular disease Redo Surgical Aortic Valve Replacement Ascending aorta aneurysm Aortic root enlargement Chronic Kidney Disease with estimated Glomerular Filtration Rate less than 30 milliliters per minute Body Mass Index greater than 30 kilograms per square meter Inadequate Multidetector Computed Tomography images

Interested in this trial?

Get notified about updates and connect with the research team.

Interventions

OTHERThe measurements taken from the CT scan will be used to determine the appropriate size for two types of theoretical Transcatheter Aortic Valve Replacement (TAVR) prostheses

All patients with severe aortic stenosis (AS) who are scheduled for Surgical Aortic Valve Replacement (SAVR) with a bioprosthetic valve will undergo a pre-operative Computed Tomography (CT) scan. This CT scan will follow the pre-Transcatheter Aortic Valve Replacement (pre-TAVR) protocol and will focus only on imaging the aortic root, using a method called retrospective electrocardiogram (ECG) gating to capture detailed heart motion. The measurements taken from the CT scan will be used to determine the appropriate size for two types of theoretical Transcatheter Aortic Valve Replacement (TAVR) prostheses:


Locations(1)

Maria Cecilia Hospital

Cotignola, Ravenna, Italy

View Full Details on ClinicalTrials.gov

For the most up-to-date information, visit the official listing.