HeartR™ PDA Occluder Post-Market Follow-Up Study
Lifetech Scientific (Shenzhen) Co., Ltd.
140 participants
Apr 30, 2025
OBSERVATIONAL
Conditions
Summary
The HeartR™ PDA Occluder Post-Market Clinical Follow-up (PMCF) Study is a multi-center, retrospective, single-arm study sponsored by Lifetech Scientific (Shenzhen) Co., Ltd., aiming to evaluate the long-term safety and performance of the Lifetech HeartR™ PDA Occluder in real-world clinical practice in Indonesia. A total of 140 subjects diagnosed with Patent Ductus Arteriosus (PDA) and treated with the HeartR™ PDA Occluder according to the Instructions for Use (IFU) will be enrolled. Eligible subjects include patients aged ≥6 months, weighing ≥6 kg, with a PDA narrowest diameter ≥2 mm at the time of implantation. Patients without any follow-up visit after hospital discharge will be excluded from the study. The primary endpoint is procedural success at 12 months post-implantation, defined as the absence of major adverse events including stroke/TIA, device embolization, cardiac or vascular perforation, left pulmonary artery stenosis or aortic stenosis requiring re-intervention, and procedure/device-related death, together with complete defect closure confirmed by Doppler echocardiography without residual shunt. Secondary endpoints include complete closure rates before discharge and at 6 months post-implantation, incidence of left pulmonary artery stenosis or aortic stenosis requiring re-intervention, incidence of device- or procedure-related adverse events (AEs) and serious adverse events (SAEs), as well as all-cause mortality through 24 months post-implantation.
Eligibility
Inclusion Criteria4
- Patients with a confirmed diagnosis of Patent Ductus Arteriosus (PDA) and were implanted with the HeartR™ PDA Occluder as per IFU instructions
- Age ≥ 6 months at the time of implantation.
- Weighing ≥ 6 kg at the time of implantation.
- Narrowest portion of the PDA ≥ 2mm at the time of implantation.
Exclusion Criteria1
- Patients did not conduct any follow up visit after hospital discharge.
Interested in this trial?
Get notified about updates and connect with the research team.
Interventions
Lifetech HeartR™ PDA Occluder used for transcatheter closure of Patent Ductus Arteriosus (PDA).
Locations(1)
View Full Details on ClinicalTrials.gov
For the most up-to-date information, visit the official listing.
NCT07646704