RecruitingNot ApplicableNCT07701343

tACS for Working Memory in Schizophrenia

Efficacy and Mechanisms of Transcranial Alternating Current Stimulation in Improving Working Memory in Patients With Schizophrenia


Sponsor

Central South University

Enrollment

30 participants

Start Date

Jul 6, 2026

Study Type

INTERVENTIONAL

Conditions

Summary

This study is a randomized, single-blind, sham-controlled crossover trial enrolling 30 schizophrenia patients, each receiving one active and one sham tACS session (7-day washout), targeting P3/P4 at individual alpha frequency (2mA, 30min) during a working memory task, with accuracy and reaction time as primary outcomes, alongside EEG and neurophysiological measures, to test the efficacy and mechanisms of individualized alpha-tACS on working memory.


Eligibility

Min Age: 18 YearsMax Age: 50 Years

Plain Language Summary

Simplified for easier understanding

This clinical trial is studying a medical device called sham stimulation and a medical device called transcranial alternating current stimulation for people with schizophrenia and working memory. The study is currently recruiting participants at 1 location. People eligible for this study include aged 18 Years to 50 Years.

This summary was AI-generated to explain the trial in plain language. It is not medical advice. Always discuss eligibility with your doctor before enrolling in a clinical trial.

Interested in this trial?

Get notified about updates and connect with the research team.

Interventions

DEVICEtranscranial alternating current stimulation

For montage 1, active electrode at P3 (10-10 system), return electrodes at P1, P5, PO3, CP3. For montage 2, active electrode at P4, return electrodes at P2, P6, PO4, CP4. Conductive paste ensures impedance \<10 kΩ. Individual alpha frequency is used, calculated before each session from mean EEG at P3/P4 during SIRP task. Stimulation intensity is 2 mA (peak-to-zero) via electric field modeling. Stimulation is delivered during SIRP task, 30 min total per session (including 15s ramp-up/down), with continuous sine wave output.

DEVICEsham stimulation

Sham stimulation provides only a 15-second ramp-up and ramp-down current at the beginning and end of each session to mimic the initial tingling or itching sensation on the scalp produced by real stimulation, but delivers no effective stimulation current during the main phase of the task period.


Locations(1)

The Second Xiangya Hospital of Central South University

Changsha, Hunan, China

View Full Details on ClinicalTrials.gov