RecruitingNot ApplicableNCT05835817

Magnetoencephalography by Optical Pumping Magnetometer


Sponsor

Centre Hospitalier Universitaire, Amiens

Enrollment

70 participants

Start Date

Apr 11, 2023

Study Type

INTERVENTIONAL

Conditions

Summary

MagnetoEncephaloGraphy (MEG) is a method of recording brain activity with high temporal resolution and good spatial resolution, compared to current recording techniques such as ElectroEncephaloGraphy (EEG). The main limitation of MEG is its cost due to the sensors used, the Super Quantum Interference Devices (SQUID). These require a complex infrastructure from an instrumentation point of view to operate, requiring liquid helium, most often at a loss, at increasing cost. Optical Pumping Magnetometers (OPM) type sensors represent a promising alternative to SQUIDs sensors, especially since they do not require helium cooling. The purpose of this project is to Identify biomarkers in Magnetoencephalography of normal brain development in healthy adults, premature and term newborns from "a priori" obtained by the classical technique of High Resolution EEG performed.


Eligibility

Min Age: 1 Day

Inclusion Criteria13

  • For healthy adult volunteers
  • Age between 18 and 65
  • No pathology, no treatment
  • No toxicant intake
  • For term newborns
  • Child between 38 and 42 weeks gestational age on the day of registration
  • No pathology, no treatment
  • For children born prematurely
  • Child between 28 and 36 weeks gestational age on the day of registration
  • No pathology, no treatment apart from routine care related to prematurity
  • For pregnant women
  • Pregnant with between 28 to 40 weeks gestational age on the day of registration
  • No pathology, no treatment

Exclusion Criteria4

  • Subject and Patients "not compatible" MEG. Wearers of prosthesis or pacemaker likely to generate artefacts interfering with the measurement. There is no danger to the subject, but the measurement itself may be impossible.
  • Patients who cannot stand to stand still for a few minutes.
  • Newborn on ventilatory assistance or infusion
  • Newborn baby not meeting the age criteria

Interested in this trial?

Get notified about updates and connect with the research team.

Interventions

OTHERMagnetoencephalography

40 minutes of Magnetoencephalography with Optical Pump Magnetometer


Locations(1)

CHU Amiens

Amiens, France

View Full Details on ClinicalTrials.gov

For the most up-to-date information, visit the official listing.

Visit

NCT05835817