RecruitingNot ApplicableNCT06491017

Effects of Mechanical Insufflation-Exsufflation With Optimized Settings on Wet Mucus Volume During Invasive Ventilation

Effects of Mechanical Insufflation-Exsufflation With Optimized Settings on Suctioned Wet Mucus Volume During Invasive Ventilation


Sponsor

Hospital Clinic of Barcelona

Enrollment

26 participants

Start Date

May 8, 2026

Study Type

INTERVENTIONAL

Conditions

Summary

Retention of airway secretions is a frequent complication in critically ill patients requiring invasive mechanical ventilation (MV).This complication is often due to excessive secretion production and ineffective secretion clearance. Mechanical insufflator-exsufflator (MI-E) is a respiratory physiotherapy technique that aims to assist or simulate a normal cough by using an electro-mechanical dedicated device. A positive airway pressure is delivered to the airways, in order to hyperinflate the lungs, followed by a rapid change to negative pressure that promotes a rapid exhalation and enhances peak expiratory flows. However, there is no consensus on the best MI-E settings to facilitate secretion clearance in these patients. Inspiratory and expiratory pressures of ±40 cmH2O and inspiratory-expiratory time of 3 and 2 seconds, respectively, are often used as a standard for MI-E programming in the daily routine practice, but recent laboratory studies have shown significant benefits when MI-E setting is optimized to promote an expiratory flow bias. The investigators designed this study to compare the effects of MI-E with an optimized setting versus a standard setting on the wet volume of suctioned sputum in intubated critically ill patients on invasive MV for more than 48 hours.


Eligibility

Min Age: 18 Years

Inclusion Criteria4

  • Adults (> 18yo).
  • Endotracheal intubation and invasive mechanical ventilation for > 48h and active humidification for > 24h.
  • Richmond Agitation-Sedation Scale -3 to -5.
  • Signed informed consent.

Exclusion Criteria9

  • Patients with hemodynamic instability (MAP < 60 or > 110, Heart Rate < 50 or > 130, new onset arrhythmias), respiratory instability (PEEP > 12cmH2O, SpO2 < 90% or fraction of inspired oxygen (FiO2) > 60%).
  • Undrained pneumothorax/pneumomediastinum.
  • Unstable intracranial pressure (ICP > 20mmHg or MAP < 60).
  • Severe bronchospasm.
  • Post cardiothoracic surgical patients.
  • Active pulmonary tuberculosis.
  • Bronchoesophageal or bronchopleural fistulas.
  • Prone position.
  • Pregnancy.

Interested in this trial?

Get notified about updates and connect with the research team.

Interventions

DEVICEMI-E Intervention protocol

The endotracheal tube cuff will be inflated to 40 cmH2O and MI-E device will be used to deliver MI-E in automatic mode, with 4 sets of 5 respiratory cycles each and a 1-minute interval between each set. Before initiation of the MI-E intervention protocol, the investigators will carry out a short-period test to find the appropriate MI-E settings to achieve inspiratory volumes of ≥1 liter and PEF ≥80 L/min. Concretely, inspiratory and expiratory time will always be set at 4 seconds and 2 seconds, respectively, and inspiratory flow will always be in slow mode. Once the appropriate inspiratory pressure will be found, the expiratory pressure will be initially set to exceed in 30 cmH2O the inspiratory pressure and, if required, this will be increased by 5 cmH2O until achieving a PEF ≥80 L/min with a maximum expiratory pressure of 70 cmH2O.

DEVICEStandard MI-E setting

Cough Assist E70 device (Philips Respironics, USA, Andover, Massachusetts) will be used to deliver MI-E in automatic mode, with 4 sets of 5 respiratory cycles each and a 1-minute interval between each set. During the 1-minute pause between sets, the patient will be reconnected to the ventilator to avoid desaturation and de-recruitment during procedures. PEEP will remain stable during the protocol. The standard MI-E setting will consist of in-expiratory pressures of +40/-40 cmH2O, medium inspiratory flow, with 3 seconds and 2 seconds of in-expiratory time, respectively, and 1-second pause.


Locations(1)

Hospital Clinic de Barcelona

Barcelona, Spain

View Full Details on ClinicalTrials.gov

For the most up-to-date information, visit the official listing.

Visit

NCT06491017


Related Trials