RecruitingNot ApplicableNCT06620328

Safety and Efficacy of Mechanical Versus Electrocautery Dilator for EUS-guided Biliary Drainage (MED-BD)

Safety and Efficacy of Mechanical Versus Electrocautery Dilator for EUS-guided Biliary Drainage: A Prospective Randomized Controlled Trial


Sponsor

National Taiwan University Hospital

Enrollment

64 participants

Start Date

Jul 3, 2025

Study Type

INTERVENTIONAL

Conditions

Summary

The purpose of this study is to investigate the likelihood of post-dilation bleeding using mechanical or electrocautery dilation. We hypothesized that the risk of bleeding is lower in the mechanical group.


Eligibility

Min Age: 18 Years

Inclusion Criteria3

  • Failed ERCP
  • The papilla is inaccessible owing to a surgically altered anatomy or gastric outlet obstruction
  • Contraindications for PTCD such as ascites and possibility of self-tube removal

Exclusion Criteria7

  • Patients younger than 18 years old
  • Cancer infiltration of the gastric/duodenal wall within the planned puncture route
  • Patients with uncorrectable coagulopathy
  • Patients with unmanageable ascites
  • Patients with serious comorbidities that prohibited endoscopic management
  • Patients with pregnancy
  • Patients who cannot or refuse to provide informed consent

Interested in this trial?

Get notified about updates and connect with the research team.

Interventions

PROCEDUREendoscopic ultrasonography-guided biliary drainage

Skilled endosonographers performed EUS-BD with patients under conscious sedation by intravenous medication. All patients were given intravenous antibiotics prophylactically. A therapeutic curved linear array echoendoscope is positioned in the stomach with carbon dioxide insufflation. Standard 19G fine needles are used to puncture the dilated left intrahepatic bile duct or commo bile duct. Bile juice aspiration with 20ml syringe was performed to confirm intraductal puncture. After contrast medium injection, an insulated guidewire (0.025 inch VisiGlide2; Olympus Medical Systems, Tokyo, Japan) is advanced antegradely. Dilation of the needle tract is initially performed with a diathermic sheath (6Fr Cyst-Gastro set; Endoflex, Voerde, Germany) or an ultra-tapered mechanical dilator (7Fr ES Dilator; Zeon Medical Co., Tokyo, Japan) according to randomization result. If needed, additional dilation can be attempted with dilating balloon. Finally, the dedicated plastic stent or partially cover


Locations(1)

National Taiwan University Hospital

Taipei, Taiwan

View Full Details on ClinicalTrials.gov

For the most up-to-date information, visit the official listing.

Visit

NCT06620328


Related Trials