Standardized Goal-Directed vs. Self-Directed Valsalva Maneuver for the Assessment of Patent Foramen Ovale
Ottawa Heart Institute Research Corporation
488 participants
Jan 30, 2025
INTERVENTIONAL
Conditions
Summary
Ischemic stroke represents a major public health issue, leading to significant disabilities and deaths worldwide. When no clear cause for stroke is found following a comprehensive cardiovascular evaluation (no atrial fibrillation, cardiac masses, or atherosclerosis) i.e. cryptogenic stroke, it is recommended to search for a patent foramen ovale (PFO), especially in young patients. It is estimated that cryptogenic stroke accounts for 30% to 40% of ischemic strokes. Transthoracic echocardiography (TTE) with bubble study at rest and during Valsalva maneuver is the reference method for the diagnosis of PFO. The treatment of PFO using a closure device has demonstrated a significant reduction in recurrent stroke events in patients with PFO and cryptogenic stroke. The Valsalva maneuver is currently achieved using self-directed maneuver i.e. patients are instructed to ''bear down'' or ''strain as if attempting to move your bowels.'' These instructions are subjective and depend largely on individuals understanding and effort. A Goal-Directed Valsalva Maneuver using a manometer has been shown to be a more reproducible way to perform the Valsalva achieving more sensitivity in different settings such as hypertrophic cardiomyopathy but its incremental diagnostic value for the detection of PFO has not been yet evaluated. The aim of the present study is to compare the sensibility and specificity of two methods of Valsalva maneuver for the detection of PFO. We hypothesize that Goal-Directed Valsalva Maneuver will significantly increase the detection rate of PFO compared to Self-Directed Valsalva Maneuver.
Eligibility
Inclusion Criteria1
- Patients referred for a clinically indicated TTE and bubble study
Exclusion Criteria4
- Inability to provide informed consent
- Inability to insert an IV line
- Inability to perform a Self-Directed Valsalva maneuver
- Patient wishing to keep his mask on
Interested in this trial?
Get notified about updates and connect with the research team.
Interventions
For the Goal directed Valsalva maneuver, the same method patients are instructed to blow into a plastic pipe connected to the manometer device, in order to reach a pressure of 40 mmHg for at least 5 seconds. Then patients are instructed to exhale quickly.
The Valsalva maneuver is performed by the patient taking a normal (or deep) inspiration, followed by forceful expiration against a closed airway for up to 15 to 20 sec and then release of the expiratory effort on entry of saline into the right atrium.
Locations(2)
View Full Details on ClinicalTrials.gov
For the most up-to-date information, visit the official listing.
NCT06670781