TRanscAtheter TreatMent of PurE Aortic Regurgitation With VitaFlow Liberty System
Transcatheter Treatment of Pure Aortic Regurgitation With VitaFlow Liberty System: a Prospective, Multicenter Study
Ruijin Hospital
120 participants
Apr 29, 2025
INTERVENTIONAL
Conditions
Summary
This study is a prospective, multicenter, non-randomized controlled trial, planning to enroll 180 patients with pure native aortic regurgitation. On the basis of standardized medical therapy, patients will be assigned in a 1:1 ratio to undergo transfemoral transcatheter aortic valve replacement (TF-TAVR) . This prospective, multicenter trial aims to evaluate the safety and effectiveness of transfemoral TAVR using the VitaFlow™ self-expanding valve system compared to dedicated transcatheter devices in patients with PNAR. The primary endpoint is a composite of all-cause mortality, disabling stroke, and rehospitalization for heart failure, myocardial Infarction, and requiring dialysis or valve reoperation at 12 months post-procedure. Secondary endpoints include procedure-related complications, long-term clinical events, patient functional status and quality of life, bioprosthetic valve imaging follow-up, echocardiographic parameters, and treatment costs. All endpoint definitions conform to the Valve Academic Research Consortium-3 (VARC-3) criteria
Eligibility
Inclusion Criteria2
- Asymptomatic moderate-to-severe or greater isolated aortic regurgitation meeting at least one of the following criteria:
- LVEF ≤ 55% (measured by biplane Simpson's method); LVESD \> 50 mm ; LVESDi \> 22 mm/mm²; LVESVi \> 45mL/m2 Anatomical suitability for TAVR as assessed by the heart team. Provision of written informed consent by the patient or their legal guardian, with agreement to the treatment plan and willingness and ability to comply with all required follow-up assessments.
Exclusion Criteria3
- Life expectancy \< 1 year. LVEF \< 45%. eGFR \< 30 mL/min/1.73m². Known allergy or contraindication to required medications (e.g., aspirin, clopidogrel, warfarin) or contrast media.
- Any condition that precludes contrast-enhanced CT. Concurrent moderate-to-severe or severe valvular heart disease other than aortic regurgitation.
- Poor patient compliance, unable to complete follow-up as required. Any other condition that, in the investigator's judgment, would make the patient unsuitable for the study.
Interested in this trial?
Get notified about updates and connect with the research team.
Interventions
The patient will undergo transcatheter aortic valve replacement on the basis of guideline-directed medical therapy with The VitaFlow™ system. The VitaFlow™ system (MicroPort®, Shanghai, China) was a novel TAVR system, which incorporates high-radial force and a double layer polyethylene terephthalate (PET) skirt to optimize frame geometry and minimize the risks of paravalvular leak (PVL). The VitaFlow™ transcatheter aortic valve is made of a self-expanding nitinol frame and tri-leaflet bovine pericardial valve.
The patient will undergo transfemoral aortic valve replacement on the basis of guideline-directed medical therapy with The J-Valve system (Jie ChengMedical Technologies, Suzhou, China). The J-Valve system is a second-generation self-expand able device composed of a porcine bioprosthetic aortic valve and a transfemoral delivery sheath. The valve is supported by a self-expanding nitinol structure. The different valve sizes are 21, 23, 25, 27, 29 and 34 mm. Three U-shaped nitinol graspers were designed to surround the valve.
Locations(4)
View Full Details on ClinicalTrials.gov
For the most up-to-date information, visit the official listing.
NCT06818084