RecruitingPhase 4NCT06818084

TRanscAtheter TreatMent of PurE Aortic Regurgitation With VitaFlow Liberty System

Transcatheter Treatment of Pure Aortic Regurgitation With VitaFlow Liberty System: a Prospective, Multicenter Study


Sponsor

Ruijin Hospital

Enrollment

120 participants

Start Date

Apr 29, 2025

Study Type

INTERVENTIONAL

Conditions

Summary

This study is a prospective, multicenter, non-randomized controlled trial, planning to enroll 180 patients with pure native aortic regurgitation. On the basis of standardized medical therapy, patients will be assigned in a 1:1 ratio to undergo transfemoral transcatheter aortic valve replacement (TF-TAVR) . This prospective, multicenter trial aims to evaluate the safety and effectiveness of transfemoral TAVR using the VitaFlow™ self-expanding valve system compared to dedicated transcatheter devices in patients with PNAR. The primary endpoint is a composite of all-cause mortality, disabling stroke, and rehospitalization for heart failure, myocardial Infarction, and requiring dialysis or valve reoperation at 12 months post-procedure. Secondary endpoints include procedure-related complications, long-term clinical events, patient functional status and quality of life, bioprosthetic valve imaging follow-up, echocardiographic parameters, and treatment costs. All endpoint definitions conform to the Valve Academic Research Consortium-3 (VARC-3) criteria


Eligibility

Min Age: 60 Years

Plain Language Summary

Simplified for easier understanding

This clinical trial is studying J-Valve+GDMT and VitaFlow+GDMT for people with aortic valve diseases, transcatheter aortic valve replacement (tavr), and other related conditions. The study is currently recruiting participants at 4 locations.

This summary was AI-generated to explain the trial in plain language. It is not medical advice. Always discuss eligibility with your doctor before enrolling in a clinical trial.

Interested in this trial?

Get notified about updates and connect with the research team.

Interventions

COMBINATION_PRODUCTVitaFlow+GDMT

The patient will undergo transcatheter aortic valve replacement on the basis of guideline-directed medical therapy with The VitaFlow™ system. The VitaFlow™ system (MicroPort®, Shanghai, China) was a novel TAVR system, which incorporates high-radial force and a double layer polyethylene terephthalate (PET) skirt to optimize frame geometry and minimize the risks of paravalvular leak (PVL). The VitaFlow™ transcatheter aortic valve is made of a self-expanding nitinol frame and tri-leaflet bovine pericardial valve.

COMBINATION_PRODUCTJ-Valve+GDMT

The patient will undergo transfemoral aortic valve replacement on the basis of guideline-directed medical therapy with The J-Valve system (Jie ChengMedical Technologies, Suzhou, China). The J-Valve system is a second-generation self-expand able device composed of a porcine bioprosthetic aortic valve and a transfemoral delivery sheath. The valve is supported by a self-expanding nitinol structure. The different valve sizes are 21, 23, 25, 27, 29 and 34 mm. Three U-shaped nitinol graspers were designed to surround the valve.


Locations(4)

Ruijin hospital, Shanghai JiaoTong University School of Medicine

Shanghai, Shanghai Municipality, China

Shanghai Chest Hospital

Shanghai, Shanghai Municipality, China

Zhongshan Hospital, Fudan University

Shanghai, Shanghai Municipality, China

Changhai Hospital

Shanghai, Shanghai Municipality, China

View Full Details on ClinicalTrials.gov

For the most up-to-date information, visit the official listing.

Visit

NCT06818084


Related Trials