TRanscAtheter TreatMent of PurE Aortic Regurgitation With VitaFlow Liberty System
Transcatheter Treatment of Pure Aortic Regurgitation With VitaFlow Liberty System: a Prospective, Multicenter Study
Ruijin Hospital
120 participants
Apr 29, 2025
INTERVENTIONAL
Conditions
Summary
This study is a prospective, multicenter, non-randomized controlled trial, planning to enroll 180 patients with pure native aortic regurgitation. On the basis of standardized medical therapy, patients will be assigned in a 1:1 ratio to undergo transfemoral transcatheter aortic valve replacement (TF-TAVR) . This prospective, multicenter trial aims to evaluate the safety and effectiveness of transfemoral TAVR using the VitaFlow™ self-expanding valve system compared to dedicated transcatheter devices in patients with PNAR. The primary endpoint is a composite of all-cause mortality, disabling stroke, and rehospitalization for heart failure, myocardial Infarction, and requiring dialysis or valve reoperation at 12 months post-procedure. Secondary endpoints include procedure-related complications, long-term clinical events, patient functional status and quality of life, bioprosthetic valve imaging follow-up, echocardiographic parameters, and treatment costs. All endpoint definitions conform to the Valve Academic Research Consortium-3 (VARC-3) criteria
Eligibility
Plain Language Summary
Simplified for easier understanding
This summary was AI-generated to explain the trial in plain language. It is not medical advice. Always discuss eligibility with your doctor before enrolling in a clinical trial.
Interested in this trial?
Get notified about updates and connect with the research team.
Interventions
The patient will undergo transcatheter aortic valve replacement on the basis of guideline-directed medical therapy with The VitaFlow™ system. The VitaFlow™ system (MicroPort®, Shanghai, China) was a novel TAVR system, which incorporates high-radial force and a double layer polyethylene terephthalate (PET) skirt to optimize frame geometry and minimize the risks of paravalvular leak (PVL). The VitaFlow™ transcatheter aortic valve is made of a self-expanding nitinol frame and tri-leaflet bovine pericardial valve.
The patient will undergo transfemoral aortic valve replacement on the basis of guideline-directed medical therapy with The J-Valve system (Jie ChengMedical Technologies, Suzhou, China). The J-Valve system is a second-generation self-expand able device composed of a porcine bioprosthetic aortic valve and a transfemoral delivery sheath. The valve is supported by a self-expanding nitinol structure. The different valve sizes are 21, 23, 25, 27, 29 and 34 mm. Three U-shaped nitinol graspers were designed to surround the valve.