A Study of Transcatheter Aortic Valve Replacement Case Selection and Valve Sizing Using the ABC Bicuspid Sizing Algorithm
A Prospective Cohort Study of Bicuspid Case Selection and Valve Sizing Using the ABC Bicuspid Sizing Algorithm for Sapien 3 Balloon Expandable Valve
World Health Research Inc.
290 participants
May 13, 2025
OBSERVATIONAL
Conditions
Summary
The goal of this study is to learn what effects the ABC Bicuspid Sizing Algorithm has on the clinical outcomes of patients with bicuspid aortic stenosis after having a transcatheter aortic valve replacement (TAVR) using the Sapien 3 valve. The main questions the study aims to answer are: 1. Does the ABC Bicuspid Sizing Algorithm increase the technical success at exit from the procedure room? 2. Does the ABC Bicuspid Sizing Algorithm increase the device success at 30 days after the procedure? Participants already being evaluated for a TAVR as part of their regular medical care for bicuspid aortic stenosis will have their diagnostic images assessed using the ABC Bicuspid Sizing Algorithm to help determine their procedure type and valve size. They will have visits 30 days and one year after their procedure.
Eligibility
Inclusion Criteria6
- Have bicuspid aortic valve disease
- Have severe aortic stenosis or mixed aortic stenosis and regurgitation requiring treatment
- Have no other condition requiring surgical intervention
- Have had a TAVR CT scan (retrospectively gated contrast enhanced acquisition) that is of diagnostic quality and includes multiphase reconstructions of the aortic root at the minimum available slice thickness (with at least three systolic and one diastolic phases)
- Would be treated with a Sapien 3 valve if found to be anatomically suitable for TAVR
- Have a suitable access route for TAVR with a Sapien 3 valve
Exclusion Criteria2
- Are treated with TAVR using a device other than a Sapien 3 valve
- Are unable to be treated with TAVR due to intercurrent illness, clinical instability, or death on waitlist after being accepted for TAVR
Interested in this trial?
Get notified about updates and connect with the research team.
Interventions
The ABC Bicuspid Sizing Algorithm is a valve sizing algorithm. It guides operators' evaluations of CT scans, helping inform (1) treatment allocation between TAVR and surgical aortic valve replacement, and (2) valve choice for patients undergoing TAVR. In select cases, the algorithm will suggest gated CT evaluation or artificial intelligence-based simulation models be used to further evaluate the risk of the planned valve size and deployment volume. The operators will consider the findings of the ABC Bicuspid Sizing Algorithm as well as other clinical factors when making their final treatment decisions.