RecruitingNot ApplicableNCT07207005

Comparison of Wear Between Two Dual-mobility Acetabular Cups in Patients Undergoing Total Hip Arthroplasty


Sponsor

GCS Ramsay Santé pour l'Enseignement et la Recherche

Enrollment

96 participants

Start Date

Jul 30, 2026

Study Type

INTERVENTIONAL

Conditions

Summary

In 2022, data from the UK's National Joint Registry (NJR) and the American Joint Replacement Registry (AJRR) indicated that Total Hip Replacement (THR) is the most commonly performed orthopaedic joint surgery. The NJR has observed that between 10 and 20% of hip implants require revision within the first 10 years. The main reasons for these revisions include implant fractures, joint incompatibility, aseptic loosening, dislocation and wear of the polyethylene (PE) insert. To address this problem, highly cross-linked polyethylene (HXLPE) inserts have been developed. Cross-linking helps to limit wear on polyethylene prostheses in total hip arthroplasty. However, there are concerns about the loss of elasticity of HXLPE and oxidation after implantation. A new generation of inserts based on highly cross-linked polyethylene (irradiation dose ≥100 Kgy), enriched with vitamin E, has been developed. This PE, called ECIMA, was developed to maintain mechanical properties, minimise PE wear and improve long-term oxidation resistance. In the HAS evaluation report on highly cross-linked polyethylene inserts dated 24 January 2023, data from the literature show less wear of highly cross-linked polyethylene compared to conventional polyethylene. Nevertheless, the use of highly cross-linked polyethylene is not yet the gold standard. Furthermore, the data in the literature mainly concern single-mobility cups but not double-mobility cups. Finally, new imaging protocols now make it possible to assess the wear of prosthesis materials more accurately. In this context, it seems appropriate to conduct a French study comparing double-mobility cups containing highly cross-linked polyethylene or conventional polyethylene inserts.


Eligibility

Min Age: 55 YearsMax Age: 80 Years

Plain Language Summary

Simplified for easier understanding

This clinical trial is studying a medical device called CORIN and a medical device called ECIMA CORIN for people with hip arthroplasty replacement. The study is currently recruiting participants at 1 location.

This summary was AI-generated to explain the trial in plain language. It is not medical advice. Always discuss eligibility with your doctor before enrolling in a clinical trial.

Interested in this trial?

Get notified about updates and connect with the research team.

Interventions

DEVICEECIMA CORIN

Mobile cup (Corin) made of highly cross-linked PE doped with vitamin E (ECIMA, Corin).

DEVICECORIN

Mobile cupule (Corin) is made of conventional PE