RecruitingNot ApplicableNCT07437846

Impact of PEEP on Respiratory Effort During Assisted Ventilation

Impact of Positive End-Expiratory Pressure on the Modulation of Respiratory Effort During Assisted Ventilation: A Physiological Randomized Crossover Study


Sponsor

Pontificia Universidad Catolica de Chile

Enrollment

12 participants

Start Date

Jan 1, 2025

Study Type

INTERVENTIONAL

Conditions

Summary

Assisted mechanical ventilation is widely used to preserve diaphragmatic activity and improve lung aeration in patients with acute respiratory failure. However, during assisted ventilation, excessive inspiratory effort may develop and contribute to lung injury, diaphragmatic overload, and patient self-inflicted lung injury. Optimizing ventilator settings to modulate respiratory effort therefore represents a major physiological and clinical challenge. Positive end-expiratory pressure (PEEP) is a key determinant of lung recruitment and respiratory system mechanics and may influence inspiratory effort by modifying lung volume, compliance, and respiratory drive. Despite its widespread use, PEEP titration in clinical practice is still mainly guided by oxygenation parameters, while its direct effects on inspiratory effort during assisted mechanical ventilation remain insufficiently characterized. This physiological randomized crossover study aims to evaluate the effect of four predefined levels of positive end-expiratory pressure (0, 5, 10, and 15 cmH₂O) on the respiratory system and inspiratory effort in adult patients receiving assisted mechanical ventilation. Patients will be exposed to each PEEP level in randomized order, with stabilization and washout periods between conditions, while ventilatory support settings other than PEEP are kept constant.


Eligibility

Min Age: 18 Years

Inclusion Criteria6

  • Age ≥18 years.
  • ICU patients receiving invasive mechanical ventilation (endotracheal tube or tracheostomy).
  • Ventilated in an assisted mode with spontaneous breathing
  • Clinically stable to undergo protocolized PEEP changes.
  • Sedation level compatible with spontaneous breathing and ventilator triggering
  • Informed consent from the patient or legally authorized representative.

Exclusion Criteria7

  • Contraindication to esophageal balloon placement (if applicable).
  • Significant hemodynamic instability or unstable vasopressor requirements.
  • Unstable arrhythmia or active myocardial ischemia.
  • Undrained pneumothorax or major air leak.
  • Controlled ventilation without effective spontaneous effort (apnea, neuromuscular blockade, deep sedation).
  • Pregnancy
  • Acute or chronic neurological conditions that may impair respiratory drive or interfere with the regulation of spontaneous breathing.

Interested in this trial?

Get notified about updates and connect with the research team.

Interventions

OTHERPEEP Level Adjustment

Positive end-expiratory pressure (PEEP) will be adjusted to four predefined levels (0, 5, 10, and 15 cmH₂O) following a randomized crossover protocol during assisted mechanical ventilation. Only the PEEP level will be modified, while all other ventilator settings will be kept constant. Each PEEP level will be maintained for 15 minutes, followed by a 15-minute washout period between levels. Physiological measurements will be obtained during the last 5 minutes of each PEEP level, including respiratory effort assessed using invasive and non-invasive methods, respiratory mechanics, and hemodynamic parameters.


Locations(1)

Hospital Clinico UC

Santiago, Santiago Metropolitan, Chile

View Full Details on ClinicalTrials.gov

For the most up-to-date information, visit the official listing.

Visit

NCT07437846


Related Trials