Endoscopic Ultrasound Shear Wave Elastography in Patients With Non-alcoholic Fatty Liver Disease
Endoscopic Ultrasound Shear Wave Elastography: A Novel Tool for Fibrosis Screening in Patient With Elevated Body Mass Index and Suspected Non-Alcoholic Fatty Liver Disease or Steatohepatitis
Brigham and Women's Hospital
150 participants
Jun 1, 2021
OBSERVATIONAL
Conditions
Summary
The goal of this observation study is to assess whether endoscopic ultrasound shear wave elastography (EUS-SWE) may be a useful tool for liver fibrosis screening in patients with elevated body mass index and non alcoholic fatty liver disease as compared to other non-invasive screening modalities, which have traditionally had less accurate results in this population. The main questions it aims to answer are: * Determine accuracy of EUS-SWE for liver fibrosis screening compared to other non-invasive scoring systems, such as the FIB-4 score and Fibroscan in patients with elevated body mass index * Establish optimal stiffness (kPa) cutoffs for liver fibrosis grading for EUS-SWE for this patient population in reference to the gold standard liver biopsy, as no standard cutoffs currently exist. Participants will undergo routine endoscopic ultrasound as part of their standard clinical care and indication. Participants are consented for the procedure and undergoing the shear wave elastography. In addition to their standard ultrasound test, it takes on average an extra 2-3 minutes to perform the shear wave elastography. The procedure itself adds no additional risk to the patient and does not expose them to radiation.
Eligibility
Inclusion Criteria4
- Adults 18 years or older
- Planned for clinically indicated endoscopic ultrasound with plan for follow up liver biopsy
- Suspected or confirmed non alcoholic fatty liver disease prior to procedure
- Body mass index \>=25
Exclusion Criteria1
- Inadequate liver biopsy sample
Interested in this trial?
Get notified about updates and connect with the research team.
Interventions
To perform the portion of the endoscopic ultrasound exam using this device, the endoscopic ultrasound probe is placed onto the surface of the stomach with the probe facing the left liver. The probe then transmits shear waves that propagate through the tissue. The waves themselves are ultrasound waves and are harmless. This is repeated 10 times on a region of interest as guided by the endoscopic ultrasound probe. The device used in question is the linear EUS (Aloka Arietta 850, Olympus America, Center Valley, PA).