RecruitingNot ApplicableNCT06474559

Comparison of Lma-Protector With Endotracheal Tube: Evaluation of Respiratory Mechanical Parameters During Controlled Ventilation & Possibility of Pulmonary Aspiration

Comparison of Protector Laryngeal Mask With Endotracheal Tube: Evaluation of Respiratory Mechanical Parameters During Controlled Ventilation & Possibility of Pulmonary Aspiration


Sponsor

University Hospital of Patras

Enrollment

80 participants

Start Date

Jun 1, 2024

Study Type

INTERVENTIONAL

Conditions

Summary

The aim of this prospective, randomized, comparative, controlled clinical study is to compare laryngeal mask airway ProtectorTM with the endotracheal tube, regarding to the respiratory mechanical parameters during controlled mechanical ventilation and the prevalence of aspiration. Aspiration will be evaluated by detecting and quantifying pepsin (a marker of gastric aspiration) and α-amylase (a marker of salivary aspiration) in the bronchoalveolar lavage ( mini BAL) of patients ≥18 years old, ASA 1-2, undergoing selective low-risk surgery under general anesthesia in a lithotomy position.


Eligibility

Min Age: 18 Years

Inclusion Criteria1

  • Patients aged ≥18 years ASA1-2 who are to undergo planned urological surgery of low or intermediate severity, under general anesthesia in the lithotomy position.

Exclusion Criteria8

  • patients < 18 years old.
  • Patients who are going to undergo an emergency/urgent operation/ trauma patients.
  • Maternal population.
  • Patients who are not scheduled to receive general anesthesia, but some other type of anesthesia.
  • Patients in whom LMA placement is contraindicated, such as patients at high risk for reflux and aspiration of gastric contents (eg, history of gastroesophageal reflux, hiatal hernia, pyloric stenosis, gastrointestinal obstruction, morbid obesity).
  • Patients who meet at least one of the four RODS difficulty criteria.
  • Contraindicated patients: administration of neuromuscular blockade, suppression of spontaneous respiration, and those with an indication for awake intubation or surgical airway.
  • Patients who refuse to participate in the study.

Interested in this trial?

Get notified about updates and connect with the research team.

Interventions

DEVICELMA Protector

LMA Protector will be inserted by a researcher after standard anesthesia induction. The view of the larynx will be assessed using fiberoptic grading scale.Mini bronchoalveolar lavage will be collected before the end of the procedure

DEVICEEndotracheal tube

tracheal intubation will be perform after standard anaesthetic induction. Cormack Lehane will be recorded. Mini bronchoalveolar lavage will be collected before the end of the procedure


Locations(1)

General Univerisity Hospital of Patras

Pátrai, Greece

View Full Details on ClinicalTrials.gov

For the most up-to-date information, visit the official listing.

Visit

NCT06474559


Related Trials