RecruitingNCT06895590
The HIgh-fidelity Hydraulic couPling Upper-arm Cuff Assessment of Limits, Safety, and Effectiveness (HIPULSE) Trial
Sponsor
Philips Clinical & Medical Affairs Global
Enrollment
205 participants
Start Date
Oct 2, 2025
Study Type
OBSERVATIONAL
Conditions
Summary
The purpose of this study is to compare measurements of blood pressure (BP) and fluid responsiveness between the Philips AMC and invasive radial arterial line in surgical patients.
Eligibility
Min Age: 18 Years
Inclusion Criteria18
- Adults aged 18 years and older
- Indication for NIBP cuff
- Indication for a radial arterial line
- Subject or legal authorized representative is able to understand and speak the local language (also Spanish for US sites) to provide voluntary written informed consent prior to study procedures
- The following stratification criteria must be met across the study sites and hence targeted enrollment may be required:
- Age of every patient 18+; at least 30% > 65 years, 30% ≤ 65 years
- At least 30% male, 30% female
- Minimum number of subjects needed to test each size cuff (per ISO81060-2:2018/AMD2:2024, based on limb circumference range):
- Adult Small (19-27 cm) = 165*\[8/(2*24)\] = 28
- Adult (25-34 cm) = 165*\[9/(2*24)\] = 31
- Adult Large Short (30-40 cm with severely conical arm) = 165*\[10/(2*24)\] = 35
- Adult Large (32-43 cm) = 165*\[11/(2*24)\] = 38
- At least 40% of the subjects within each cuff size shall have a limb circumference that lies within the upper half of the specified range of use of the cuff
- At least 40% of the subjects within each cuff size shall have a limb circumference within the lower half of the specified range of use of the cuff
- At least 10% SBP measurements ≤ 100 mmHg
- At least 10% SBP measurements ≥ 160 mmHg
- At least 10% DBP measurements ≤ 70 mmHg
- At least 10% DBP measurements ≥ 85 mmHg
Exclusion Criteria13
- Emergency surgery
- Surgeries in which both arms are tucked
- Inability to place the Philips AMC appropriately due to subject anatomy or condition
- Known pregnancy or lactating women (self-report)
- Patients treated with an intra-aortic balloon pump
- Aortic and mitral regurgitation (> 2nd degree), if known
- Measurements taken in the lateral position
- Pressure of the arterial line system, when tested at 100 mmHg with the VeriCal device, exceeds the +/- 2 mmHg threshold
- Currently participating in an investigational drug or another device study that clinically interferes with the study endpoints
- Upper arm circumference < 19 cm or > 43 cm
- BMI > 45
- If the average of 3 baseline NIBP lateral difference measurements for SBP is > 15 mmHg or for DBP is > 10 mmHg
- At the PI's discretion, subject does not qualify to participate in the study for any reasons that are not mentioned above
Interested in this trial?
Get notified about updates and connect with the research team.
Interventions
DEVICEPhilips Advanced Monitoring Cuff (i.e. AMC)
Investigational, non-invasive upper arm cuff
Locations(4)
View Full Details on ClinicalTrials.gov
For the most up-to-date information, visit the official listing.
NCT06895590
Related Trials
Virtual Reality for Recovery After Intensive Care (PICS)
NCT075855001 location
CALLY Index, Frailty and SOFA-2 for Mortality Prediction in Geriatric ICU Patients
NCT075797281 location
Using a Hypotension Prediction Index to Prevent Low Blood Pressure During Dialysis in ICU Patients
NCT071797051 location
Canadian Critical Care Comparative Effectiveness Platform
NCT066051448 locations
Virtual Reality Use for ICU Mobility
NCT072342011 location