RecruitingNot ApplicableNCT07478926

Flow Detection in Open and Closed Shunt Valve Periods

Detection of Flow in Cerebrospinal Fluid Shunts With a Wireless Thermal Flow Detection Device During Open and Closed Shunt Periods


Sponsor

Rhaeos, Inc.

Enrollment

55 participants

Start Date

Jan 27, 2026

Study Type

INTERVENTIONAL

Conditions

Summary

This study is evaluating a new, noninvasive device designed to detect whether cerebrospinal fluid (CSF) is flowing through a surgically implanted shunt. CSF shunts are commonly used to treat hydrocephalus, but it can be difficult to tell whether a shunt is working properly without invasive testing or imaging that does not directly measure flow. The study device is a small, wireless sensor placed on the skin over the shunt tubing, typically near the collarbone. It uses gentle, controlled warmth to measure temperature changes that indicate whether fluid is flowing inside the shunt. The device does not break the skin and does not change a participant's medical care. This study will enroll children and adults who already have a CSF shunt and who do not have new or worsening symptoms of shunt malfunction. All participants will have a measurement taken while their shunt valve is at its usual prescribed setting. Some participants with programmable shunt valves will also have a second measurement taken after their valve is temporarily adjusted to a setting intended to stop or greatly reduce flow ("virtual off"). After this measurement, the valve will be returned to its prescribed setting. The study device results will not be shown to participants or their medical providers and will not be used to make treatment decisions. The goal of the study is to determine how well the device can distinguish between shunts that are allowing flow and those that are not. Participants will be monitored for a short period after device use and, if applicable, after any valve adjustment. The main risks of participation are mild skin irritation from the adhesive or temporary symptoms related to valve adjustment. Participants are not expected to receive a direct medical benefit, but the information gained may help improve future diagnosis of shunt function.


Eligibility

Plain Language Summary

Simplified for easier understanding

This study tests a small, non-invasive wireless device worn on the skin to detect whether cerebrospinal fluid (CSF) is flowing through a surgically implanted brain shunt — a tube used to treat hydrocephalus (excess fluid on the brain). Knowing whether a shunt is working is currently difficult without invasive procedures or imaging, and this thermal sensor device may offer a safer, simpler way to check shunt function. Both children and adults with an existing ventricular CSF shunt who do not have new or worsening symptoms of shunt malfunction are eligible, provided the shunt tubing is palpable near the collarbone and the overlying skin is intact. Participation involves having the sensor placed on the skin over the shunt tubing and, for some participants, having the shunt valve temporarily adjusted; the device results will not affect medical treatment decisions. This summary was prepared using AI to help patients understand the study in plain language.

This summary was AI-generated to explain the trial in plain language. It is not medical advice. Always discuss eligibility with your doctor before enrolling in a clinical trial.

Interested in this trial?

Get notified about updates and connect with the research team.

Interventions

DEVICERhaeos Shunt Monitoring System

characters, and fully aligned with your protocol: The intervention consists of use of a noninvasive, wireless thermal flow detection device to assess cerebrospinal fluid (CSF) flow in an existing implanted shunt. The device is externally applied to intact skin over the shunt tubing, typically near the clavicle, and delivers controlled, imperceptible thermal energy while measuring resulting temperature gradients associated with CSF flow. Measurements are performed using a sponsor-provided tablet application that encodes results to maintain blinding. In some participants with programmable shunt valves, measurements are obtained under both prescribed flow-permissive settings and a temporary manufacturer-reported "virtual off" valve setting, after which the valve is returned to the prescribed setting. Device data are collected for research purposes only and are not used to guide clinical care.


Locations(1)

OSF Healthcare

Peoria, Illinois, United States

View Full Details on ClinicalTrials.gov